Bringing your GreenSeeker Sensor back to LIFE!
Charging
IPAQ The IPAQ can be left on the charger for extended
periods without risk of damaging the battery
Senor The Sensor should not be
left on the charger for extended periods. Charge the sensor after each
use for approximately 12 hrs, then place back onto the charger 12 hrs prior
to next use if the sensor has been off the charger for over a week.
THE IPAQ DOES NOT CHARGE ON THE SENSOR WHEN THE
SENSOR IS TURNED OFF.
N-Rich Strip
- Turn on Sensor
- Turn on Ipaq
- Click
- Start
- Programs
- N-Tech Capture
- Choose log strip Option
- For sensors distributed prior to Jan 2007
- On the bottom of the screen select sensor
i.
Select start Green seeker.
- Message should appear “Press Trigger to Log”
- Select the Button to the right of the NR Strip or
Farmer Practice, which ever you plan to sense first, the button will say
MONITORING.
- Press trigger while walking though NR or FP
- Do the same for the next practice.
- Record NDVI Readings from both N-Rich and Farmers
Practice for later use.
- Bottom Left hand corner of IPAQ select
- File
- Save As
- Input File name
- Select Folder to store file ex. N-Tech Capture
or Ramp Sensed File
- Save
- Before sensing next field: Go To Bottom Left Hand
Corner
- File
- New
- When you are ready to calculate the N Rate for the
field (using the IPAQ).
- Bottom Left hand corner of IPAQ select
- File
- Exit
- On IPAQ click
- Start
- File Explorer
- Open the My Device folder ( top left hand side
of the sceen)
- In My Device open My Documents
- Open pocket excel file named Oklahoma Loadup
- IMPORTANT Do Not Click on or Write in
RED BOXES!!
- Enter Max Yield (2 times the ave) into the yellow box.
a. First tap on the Yellow Box for Max yield
b. On the bottom center of the screen hit the icon that
looks like a keyboard.
c. Input the numbers.
- Do the same for GDD>0, which has to be calculated before going to
the field,
NDVI (NRS), NDVI (FP), and NUE Expected.
- Tap once on the keyboard on the bottom of the screen, to hide the
keyboard.
- Results in the Red Boxes are the YP and N Rate for that field..
Ramp Calibration Strip
- Turn on Sensor
- Turn on IPAQ
- Click
- Start
- Programs
- N-Tech Capture
- Choose log plot Option
- For sensors distributed prior to Jan 2007
- On the bottom of the screen select sensor
i.
Select start Green seeker.
- Message should appear “Press Trigger to Log”
- Press trigger while walking though the Ramp
without RELEASING trigger.
- Do Not sense the High N rate that is next to the
Zero.
- Bottom Left hand corner of IPAQ select
- File
- Save As
- Input File name
- Select Folder to store file ex. N-Tech Capture
or Ramp Sensed File
- Save
- When you are ready to analyze ramp
- Bottom Left hand corner of IPAQ select
- File
- Exit
- On the Main IPAQ Screen Click
- Start
- Programs or Shortcut to Ramp_Mobile
- Shortcut to Ramp_Mobile_Analysis
- On the bottom Left hand Side select
- Settings
- Ramp Config
- Load Config File (If using Standard ramp)
- Click on either 16 step or 8 step ramp
- Select Settings Again
- Field Settings
- Fill in Field ID, GDD, Est Yield, NUE, and
Growth
- On the bottom Left hand Side select
- File
- Open Data
- Click on Ramp File. (Do Not Select file with
Avg or DI at the end of the field ID)
- Click Analyze Button.
|